Available calcium levels in central nervous system for Arzenazo III method

Breadcrumb

  • Home
  • Available Calcium Levels In Central Nervous System For Arzenazo III Method
  • Available calcium levels in central nervous system for Arzenazo III method

Rogério de Freitas Lacerda 1, * and Isabela Cristina Sena Romano 2

1 Biological and Nature Sciences Center, Federal University of Acre, Rio Branco, AC, Brazil.
2 Molecular and Behavioral Neurosciences Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil.
 
Research Article
GSC Advanced Research and Reviews, 2023, 15(03), 038–045.
Article DOI: 10.30574/gscarr.2023.15.3.0167
DOI url: https://doi.org/10.30574/gscarr.2023.15.3.0167
Received on 19 April 2023; revised on 30 May 2023; accepted on 02 June 2023
 
The measurement and evaluation of changes in calcium levels between cellular compartments can provide important information for the understanding of biochemical processes, both physiological and pathological. The objective of this study was to validate the use of the calcium diagnostic kit (Arzenazo III) to tissue samples from the Central Nervous System. We used 96-well, flat-bottomed microplates with an internal diameter of 6.7 mm, total height of 12 mm and actual height of 10.705 mm, bottom thickness 1.295 mm, to carry out the tests and calculation parameters, therefore, the path optic was 5.729 mm with a total volume of 202 µL per well. The microplates were incubated at 37 °C for 2 minutes. Optical densities were measured at 630 nm on the Elx800 plate reader, (BioTek, VT, USA). According to the Arzenazo III Bioclin© calcium diagnostic kit. the absorbance of the tests/samples was normalized with the absorbance of the blank (colorimetric reagent 2 - Arsenazo III – Arzenazo III Bioclin© calcium diagnostic kit). PFC, Thalamus and Hippocampus were normalized by blank and presented respectively 0.1782 ± 0.0013; 0.1296 ± 0.0102; 0.0231 ± 0.0053; 0.0170 ± 0.0051; 0.0136 ± 0.0026.  The calculation µg calcium / mg tissue obtained 0.4670 ± 0.1056 to sample PFC; 0.4322 ± 0.1228 to sample Thalamus and 0.1027 ± 0.0203 to sample Hippocampus. Although the limitations of the technique, the measurement of free calcium in the CNS tissues (PFC, Thalamus and Hippocampus) showed positive and satisfactory results, as an alternative and viable means for the quantification of calcium levels.
 
Calcium; Arzenazo-III; SNC; Microplates
https://gscarr.gsconlinepress.com/sites/default/files/fulltext_pdf/GSCARR-2023-…

Preview Article PDF

Rogério de Freitas Lacerda and Isabela Cristina Sena Romano. Available calcium levels in central nervous system for Arzenazo III method. GSC Advanced Research and Reviews, 2023, 15(3), 038-045. Article DOI: https://doi.org/10.30574/gscarr.2023.15.3.0167

Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


All statements, opinions, and data contained in this publication are solely those of the individual author(s) and contributor(s). The journal, editors, reviewers, and publisher disclaim any responsibility or liability for the content, including accuracy, completeness, or any consequences arising from its use.

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content

Copyright © 2026 GSC Advanced Research and Reviews - All rights reserved

Developed & Designed by VS Infosolution