Home
GSC Advanced Research and Reviews
Peer-reviewed | Multidisciplinary Journal | Impact factor 8.3 | ISSN: 2582-4597 | Crossref DOI

Main navigation

  • Home
    • Journal Information
    • Editorial Board Members
    • Reviewer Panel
    • Abstracting and Indexing
    • Journal Policies
    • Our CrossMark Policy
    • Publication Ethics
    • Issue in Progress
    • Current Issue
    • Past Issues
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Join Editorial Board
    • Join Reviewer Panel
  • Contact us
  • Downloads

Study the variations in radiation doses in different multi-slice CT scan machines

Breadcrumb

  • Home
  • Study The Variations In Radiation Doses In Different Multi-slice CT Scan Machines
  • Study the variations in radiation doses in different multi-slice CT scan machines

Samia A. Fathelrahman 1, *, Albosairi T. Ahmed 1, Najla H. Khalid 1, Maha Esmaeal Ahmed 2 and Hamad A. Al-bishr 3

1 Department of Radiological Sciences, Applied Medical Sciences College, Najran University, Najran KSA, P.O. Box 1989 KSA.
2 National University, Radiological sciences and Medical imaging College, Khartoum, Sudan.
3 Department of Radiology, King Khalid Hospital. MOH, KSA.
 
Research Article
GSC Advanced Research and Reviews, 2023, 17(02), 221–228.
Article DOI: 10.30574/gscarr.2023.17.2.0450
DOI url: https://doi.org/10.30574/gscarr.2023.17.2.0450
Received on 18 October 2023; revised on 25 November 2023; accepted on 28 November 2023
 
Objectives: This study aimed to measure variations in dose output and patient’s effective dose across the different computed tomography scanners during standard CT examinations of head, chest and abdomen, so as to determine patient, and machine settings that contribute to variations in radiation dose to optimize patient effective dose.
Methods: Retrospective, study performed in different hospitals, in Najran province (K.S.A) from October 2022 to June 2023. The study comprise 360 adults CT examinations. The mean values of CT dose index volume (CTDIvol) and dose length product (DLP) were measured. The patient effective dose (ED) were calculated for each protocol and compared among different CT scanners.
Results: The mean values of CTDIvol , DLP, and ED, varied across the different CT scanners, Regarding abdomen CT, the CTDIvol mean values were (5.56 mGy to 18.655 mGy) , the DLP (289.78 to 968.241 mGy/cm), and mean effective doses were (4.34 to 14.5 mSv), in chest CTs the mean values of CTDIvol were (5.05 to 14.39mGy), the DLP were (202.84 to 499.098mGy/cm), and median effective doses were (2.85 to 6.97 mSv), in head CTs the mean values of CTDIvol were (42.4to 68.278mGy), the DLP were (781 to 1209.18mGy/cm), and effective doses were (1.636 to 2.528mSv).
Conclusion: Regarding selected exams, CTDI, DLP and ED were found to be varied from low variations in head CT scan, to medium in chest CT scan and high variation in abdomen CTs among different CT scanners, The highest values of CTDI and DLP were noted in head CTs followed by abdomen, and the lowest were in chest CTs. The most factors affected the CT dose variations were the technical parameters settings, mainly the number of slices, however the scanner specifications reported some impact. Optimizing dose to a reliable standard for each anatomical part should be adjusting independently by each department according to the scanner characteristics, settings and patient factors.
 
CT; CTDI; DLP; Effective dose; Ionizing radiation
 
https://gscarr.gsconlinepress.com/sites/default/files/fulltext_pdf/GSCARR-2023-…

Preview Article PDF

Samia A. Fathelrahman, Albosairi T. Ahmed, Najla H. Khalid, Maha Esmaeal Ahmed and Hamad A. Al-bishr. Study the variations in radiation doses in different multi-slice CT scan machines. GSC Advanced Research and Reviews, 2023, 17(2), 221-228. Article DOI: https://doi.org/10.30574/gscarr.2023.17.2.0450

Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


All statements, opinions, and data contained in this publication are solely those of the individual author(s) and contributor(s). The journal, editors, reviewers, and publisher disclaim any responsibility or liability for the content, including accuracy, completeness, or any consequences arising from its use.

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content

Copyright © 2026 GSC Advanced Research and Reviews - All rights reserved

Developed & Designed by VS Infosolution