Home
GSC Advanced Research and Reviews
Peer-reviewed | Multidisciplinary Journal | Impact factor 8.3 | ISSN: 2582-4597 | Crossref DOI

Main navigation

  • Home
    • Journal Information
    • Editorial Board Members
    • Reviewer Panel
    • Abstracting and Indexing
    • Journal Policies
    • Our CrossMark Policy
    • Publication Ethics
    • Issue in Progress
    • Current Issue
    • Past Issues
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Join Editorial Board
    • Join Reviewer Panel
  • Contact us
  • Downloads

Determination of Diagnostic reference levels (DRLs) for frontal chest radiology of adult patients at Regional Hospital Center of Daloa, Côte D'Ivoire

Breadcrumb

  • Home
  • Determination of Diagnostic Reference Levels (DRLs) For Frontal Chest Radiology of Adult Patients At Regional Hospital Center of Daloa, Côte D'Ivoire
  • Determination of Diagnostic reference levels (DRLs) for frontal chest radiology of adult patients at Regional Hospital Center of Daloa, Côte D'Ivoire

Ponaho Claude KEZO 1, 2, *, Akpa Marcel AGNERO 1 and Konan Rene KAMBO 1

1 Laboratory of Environmental Sciences and Technology, University Jean Lorougnon Guede, Daloa, Cote D’Ivoire.
2 Laboratory of Nuclear Physics and Radiation Protection, University Felix Houphouet Boigny, Cote d’Ivoire.
 
Research Article
GSC Advanced Research and Reviews, 2024, 21(03), 069–073.
Article DOI: 10.30574/gscarr.2024.21.3.0438
DOI url: https://doi.org/10.30574/gscarr.2024.21.3.0438
Received on 08 October 2024; revised on 23 November 2024; accepted on 26 November 2024
 
Although, diagnostic radiology is important in medical field, it significantly contributes to the irradiation of patients. One of the major goals of medical imaging is to minimize the radiation dose to the patient without compromising the image quality needed to produce an accurate diagnosis. Therefore, it is necessary to establish the diagnostic reference levels (DRLs) in radiology in order to achieve this goal. This study aimed to determine the DRLs for the chest radiological examination at the Regional Hospital of Daloa. A DAP meter was used to acquire the dose-area product (DAP) and air kerma data of 127 adult patients ( ≥ undergoing chest examinations in the radiology room. Then the Entrance Surface Dose (ESD) calculated by weighting the dose in air by the BSF backscatter factor and DRLs in DAP and ESD were determined with the 75th percentile statistical method. The key findings showed a variation of 2.69 to 500.47cGy.cm2 and 0.388 to 10.104 mGy respectively for DAP and ESD with means of 52.314 cGy.cm2 and 2.279 mGy respectively. The respective values of DRL in DAP and ESD found in this work were 60.91 cGy.cm2 and 2.658 mGy. The comparison of the DRL values in DAP and ESD found in this work with others values has shown that they were lower than the national and international values of DRLs. This study was essential for RHC of Daloa because it has evaluated the patient doses and indicated that these doses are quietly optimized.
 

 

Optimization; Chest examination; DAP; ESD; DRLs
 
https://gscarr.gsconlinepress.com/sites/default/files/fulltext_pdf/GSCARR-2024-…

Preview Article PDF

Ponaho Claude KEZO, Akpa Marcel AGNERO and Konan Rene KAMBO. Determination of Diagnostic reference levels (DRLs) for frontal chest radiology of adult patients at Regional Hospital Center of Daloa, Côte D'Ivoire. GSC Advanced Research and Reviews, 2024, 21(3), 069-073. Article DOI: https://doi.org/10.30574/gscarr.2024.21.3.0438

Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


All statements, opinions, and data contained in this publication are solely those of the individual author(s) and contributor(s). The journal, editors, reviewers, and publisher disclaim any responsibility or liability for the content, including accuracy, completeness, or any consequences arising from its use.

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content

Copyright © 2026 GSC Advanced Research and Reviews - All rights reserved

Developed & Designed by VS Infosolution